PRTD10-1K-FG Thin Film Platinum RTD

Home | Products | Temperature Solutions | Temperature Probes | PRTD10-1K-FG Thin Film Platinum RTD

The PRTD10-1K-FG thin film platinum RTD gives you accurate, stable temperature measurement in a very small package. It fits easily inside your own probe or housing. Its 1,000 Ω platinum element responds almost linearly to temperature, so your controller sees a clean, predictable signal. It operates from −75 to 400 °C and ships fully assembled with fiberglass-insulated leads. There are no fragile splices to make, which saves time on your line. Download the datasheet for full specifications, resistance tables, and dimensions.

Why OEMs choose a thin film platinum RTD

Platinum is the material of choice when a reading has to be right today and still right years from now. Its resistance rises smoothly with temperature, which keeps calibration and signal conditioning simple. Thin-film platinum is trusted in precision work, too. NIST has calibrated thin-film platinum sensors for research as demanding as optical lattice clocks. Each PRTD10-1K-FG thin film platinum RTD starts as a platinum film on an alumina substrate. Each element is laser trimmed to ±0.1% at 0 °C. We then glass it, wire it, and fire it into a high-purity alumina housing with ceramic potting. The result is a compact, fast-responding sensor with very low drift. Stability matters as much as accuracy. The PRTD10-1K-FG drifts less than 0.25 °C per year in occupied environments, so your readings stay consistent over time.

Key features of the PRTD10-1K-FG

    • 1,000 Ω platinum element: Pt1000 sensing with an alpha of 0.00375 Ω/Ω/°C
    • Tight resistance trim: Laser trimmed to ±0.1% (±0.3 °C) at 0 °C
    • Wide temperature range: Operates from −75 to 400 °C
    • Long-term stability: Less than 0.25 °C drift per year in occupied environments
    • Small and fast: Ø0.095 in alumina housing with low thermal mass
    • Low self-heating: Designed for 1 mA excitation
    • Ready to build in: Fully assembled with 12 in, 28 AWG fiberglass-insulated leads

Applications for this thin film platinum RTD

Accuracy, a wide range, and a compact ceramic package make this thin film platinum RTD a strong fit for OEM equipment such as:
    • Ovens and kilns
    • HVAC equipment
    • Autoclaves
    • Process control systems
    • Environmental test chambers
Building heating or cooling equipment? ASHRAE technical resources are a helpful reference for HVAC&R standards and engineering practice.
PRTD10-1K-FG thin film platinum RTD in a white alumina housing with fiberglass-insulated lead wires

Simple integration into your probe assembly

As a bare sensing element, this thin film platinum RTD is ready for you to build into your own probe, housing, or assembly. It arrives fully assembled with 12 in leads and stripped ends. Its two leads are not polarized, so wiring is simple. In a 2-wire circuit, lead resistance adds to the reading. Keep lead runs short or compensate for them in your measurement. Drive the element at 1 mA to keep self-heating error low. Need more than the standard part? We offer custom lead lengths, terminations, and complete probe assemblies for OEM volumes.

Choosing the right thin film platinum RTD

The PRTD10 family uses the same laser-trimmed platinum element in different packages. Choose the PRTD10-1K-FG when you want the smallest housing for service up to 400 °C. Need a metal housing or higher temperatures? The PRTD10-1K-FG-SS316L stainless steel RTD extends the range to 540 °C. For a finished probe, see the PRTD10 Overmolded RTD Temperature Probe. Still comparing options? Our guide to selecting the right RTD for your OEM application walks through the key decisions.

PRTD10-1K-FG frequently asked questions

What is the PRTD10-1K-FG thin film platinum RTD used for?

It monitors and controls critical temperatures in industrial equipment. Common uses include ovens, kilns, HVAC equipment, autoclaves, process control, and environmental chambers.

Does it work with a standard Pt1000 input?

It is a 1,000 Ω platinum RTD with an alpha of 0.00375 Ω/Ω/°C. Many Pt1000 inputs default to a 0.00385 curve. Set your controller to the 0.00375 curve, or use the Callendar–Van Dusen coefficients in the datasheet.

Can the PRTD10-1K-FG be customized?

Yes. We offer custom lead lengths, terminations, and probe assemblies for OEM volumes. Talk to one of our engineers to spec your part.

Request a quote for the PRTD10-1K-FG

We support OEM programs from first samples through full production. Tell us about your application, and our engineers will help you spec the right part.